Technology Advantage
Yese-simbi yakawanda-yakapetwa-yakaputika-humbowo chimiro, simbi isina tsvina centrifugal mhango.
Maintenance-yemahara DC inosiyana frequency mota drive, yakatsetseka uye yakanyarara kushanda.
Microcomputer processor chaiyo kutonga, kuratidzwa kwedhijitari, kushanda kuri nyore, otomatiki kuverenga kwe centrifugal simba RCF kukosha, kumhanya uye centrifugal simba rinogona kuchinjika nekiyi imwe.
Iyo inotora fluorine-isina compressor unit, kaviri-kutenderera firiji, kupisa kwakasimba uye kutonhora kuchinjanisa kugona, kunyatso kudzora tembiricha, kutonhora nekukurumidza uye pasina kusvibiswa kwezvakatipoteredza.
10-kumhanyisa kumhanyisa uye kudzora kudzora, Chengetedza 10 mapoka ezvirongwa zvinowanzo shandiswa.
Mute otomatiki yemagetsi gonhi kukiya, iri nyore kushandisa, ine emergency yekuvhura gonhi basa.
Chitubu chekoni sleeve inoshandiswa kubatanidza rotor uye shaft huru.Iyo rotor iri nyore uye inokurumidza kuisa uye kubvisa, isina-directional, yakachengeteka uye yakavimbika.
Door kukiya, overspeed, tembiricha uye kusaenzana otomatiki kudzivirira, Kuzviongorora kukanganisa kukanganisa.
Yakapfuura ISO 9001, ISO 13485, CE, TUV chitupa.
Max Speed | 16000r/min | Max RCF | 20600*g |
Max Volume | 6*100ml | Temperature Range | -20℃~40℃ |
Timer | 1~9h/59min | Noise | ≤60dBA |
Dimension | 610*570*370mm | Net Weight | 82KG |
Speed Kururama | ±20r/min | Magetsi | AC220/100V,50/60HZ,10A |
Tembiricha Yakarurama | ±1℃ |
TGL16 Yakafanana Rotors
Rotors Nha. | Rotors mhando | Kumhanya kukuru(r/min) | Vhoriyamu(ml) | Max RCF(×g) |
No30401 | Angle rotor | 16000r/min | 12×1.5/2ml | 17940×g |
No30402 | Angle rotor | 14000r/min | 40 × 0.5ml | 19970×g |
No30403 | Angle rotor | 15000r/min | 24×1.5/2ml | 20600×g |
No30404 | Angle rotor | 13500r/min | 30×1.5/2ml | 19340×g |
No30405 | Angle rotor | 15000r/min | 16 × 5ml | 19350×g |
No30406 | Angle rotor | 14000r/min | 12 × 7ml | 16370×g |
No30407 | Angle rotor | 10000r/min | 12 × 15ml | 11840×g |
No30408 | Angle rotor | 12000r/min | 12 × 10ml | 14510×g |
No30409 | Angle rotor | 12000r/min | 8×20ml | 14510×g |
No30410 | Angle rotor | 12000r/min | 6 × 30ml | 14000×g |
No30411 | Angle rotor | 11000r/min | 6 × 50ml | 13480×g |
No30412 | Angle rotor | 10000r/min | 6 × 70ml | 10810×g |
No30413 | Angle rotor | 10000r/min | 4 × 100ml | 10310×g |
No30414 | Angle rotor | 10000r/min | 6 × 100ml | 11380×g |
No30415 | Angle rotor | 14000r/min | 6 × 10ml | 16460×g |
No30416 | Angle rotor | 15000r/min | 30 × 0.5ml | 18510×g |
No30639 | Angle rotor | 5000r/min | 24 × 15ml | 3080×g |
No30627 | Angle rotor | 5000r/min | 30 × 15ml | 3830×g |
No30437 | Swing rotor | 12000r/min | 24 pcs Capillary | 15800×g |
No30444 | Angle rotor | 11000r/min | 48×1.5/2ml | 12840×g |
No30980 | Swing rotor | 13000r/min | 4 × 5ml | 14960×g |
No30935 | Vertical rotor | 14000r/min | 16 × 5ml | 12660×g |
No30676 | Microplate rotor | 4000r/min | 2×3×48 Zvakanaka | 2300×g |
No306 | Angle rotor | 14000r/min | 4×8PCR(0.2ml) | 12070×g |
No306 | Angle rotor | 13000r/min | 6×8PCR(0.2ml) | 16080×g |
No306 | Angle rotor | 14000r/min | 8×8PCR(0.2ml) | 13390×g |
No306 | Angle rotor | 13000r/min | 12×8PCR(0.2ml) | 17220×g |