Desktop High-speed Refrigerated Centrifuge

Tsanangudzo Pfupi:

TGL yakatevedzana desktop yakakwira-kumhanya yefiriji centrifuge inoshandiswa kune mabhakitiriya, mapuroteni, nucleic acid kudhirowa, subcellular chikamu kupatsanurwa, kiriniki bvunzo sampuli yekugadzirisa, yakakodzera kurapwa, sainzi yehupenyu, biopharmaceutical, sainzi yekurima, kuchengetedza kwezvakatipoteredza uye mamwe mayunivhesiti ekutsvagisa mayunivhesiti.


Product Detail

Product Tags

Pfungwa huru

m1627625017

Technology Advantage
Yese-simbi yakawanda-yakapetwa-yakaputika-humbowo chimiro, simbi isina tsvina centrifugal mhango.
Maintenance-yemahara DC inosiyana frequency mota drive, yakatsetseka uye yakanyarara kushanda.

Microcomputer processor chaiyo kutonga, kuratidzwa kwedhijitari, kushanda kuri nyore, otomatiki kuverenga kwe centrifugal simba RCF kukosha, kumhanya uye centrifugal simba rinogona kuchinjika nekiyi imwe.

Iyo inotora fluorine-isina compressor unit, kaviri-kutenderera firiji, kupisa kwakasimba uye kutonhora kuchinjanisa kugona, kunyatso kudzora tembiricha, kutonhora nekukurumidza uye pasina kusvibiswa kwezvakatipoteredza.
10-kumhanyisa kumhanyisa uye kudzora kudzora, Chengetedza 10 mapoka ezvirongwa zvinowanzo shandiswa.

Mute otomatiki yemagetsi gonhi kukiya, iri nyore kushandisa, ine emergency yekuvhura gonhi basa.
Chitubu chekoni sleeve inoshandiswa kubatanidza rotor uye shaft huru.Iyo rotor iri nyore uye inokurumidza kuisa uye kubvisa, isina-directional, yakachengeteka uye yakavimbika.

Door kukiya, overspeed, tembiricha uye kusaenzana otomatiki kudzivirira, Kuzviongorora kukanganisa kukanganisa.
Yakapfuura ISO 9001, ISO 13485, CE, TUV chitupa.

Max Speed 16000r/min Max RCF 20600*g
Max Volume 6*100ml Temperature Range -20℃~40℃
Timer 1~9h/59min Noise ≤60dBA
Dimension 610*570*370mm Net Weight 82KG
Speed ​​​​Kururama ±20r/min Magetsi AC220/100V,50/60HZ,10A
Tembiricha Yakarurama ±1℃

TGL16 Yakafanana Rotors

Rotors Nha. Rotors mhando Kumhanya kukuru(r/min) Vhoriyamu(ml) Max RCF(×g)
No30401 Angle rotor 16000r/min 12×1.5/2ml 17940×g
No30402 Angle rotor 14000r/min 40 × 0.5ml 19970×g
No30403 Angle rotor 15000r/min 24×1.5/2ml 20600×g
No30404 Angle rotor 13500r/min 30×1.5/2ml 19340×g
No30405 Angle rotor 15000r/min 16 × 5ml 19350×g
No30406 Angle rotor 14000r/min 12 × 7ml 16370×g
No30407 Angle rotor 10000r/min 12 × 15ml 11840×g
No30408 Angle rotor 12000r/min 12 × 10ml 14510×g
No30409 Angle rotor 12000r/min 8×20ml 14510×g
No30410 Angle rotor 12000r/min 6 × 30ml 14000×g
No30411 Angle rotor 11000r/min 6 × 50ml 13480×g
No30412 Angle rotor 10000r/min 6 × 70ml 10810×g
No30413 Angle rotor 10000r/min 4 × 100ml 10310×g
No30414 Angle rotor 10000r/min 6 × 100ml 11380×g
No30415 Angle rotor 14000r/min 6 × 10ml 16460×g
No30416 Angle rotor 15000r/min 30 × 0.5ml 18510×g
No30639 Angle rotor 5000r/min 24 × 15ml 3080×g
No30627 Angle rotor 5000r/min 30 × 15ml 3830×g
No30437 Swing rotor 12000r/min 24 pcs Capillary 15800×g
No30444 Angle rotor 11000r/min 48×1.5/2ml 12840×g
No30980 Swing rotor 13000r/min 4 × 5ml 14960×g
No30935 Vertical rotor 14000r/min 16 × 5ml 12660×g
No30676 Microplate rotor 4000r/min 2×3×48 Zvakanaka 2300×g
No306 Angle rotor 14000r/min 4×8PCR(0.2ml) 12070×g
No306 Angle rotor 13000r/min 6×8PCR(0.2ml) 16080×g
No306 Angle rotor 14000r/min 8×8PCR(0.2ml) 13390×g
No306 Angle rotor 13000r/min 12×8PCR(0.2ml) 17220×g